PUT Union Tee Plastic Poly ventilabis in fistulam ad fistulam Adapter Connector Fittings
EXEMPLUM | A | D | E | F | Pondus (g) |
PUT04 | 4 | 18.8 | 10.7 | 3 | 6.1 |
PUT06 | 6 | 20.1 | 13.3 | 3 | 8.9 |
PUT08 | 8 | 22.6 | 14.5 | 3 | 10.7 |
PUT10 | 10 | 26.5 | 18.2 | 4 | 19.9 |
PUT12 | 12 | 28.3 | 20.6 | 4 | 25.1 |
PUT14 | 14 | 31 | 23.6 | 5 | 35.1 |
PUT16 | 16 | 32.5 | 25.2 | 5 | 35.2 |
EXEMPLUM | A | B | C | D | E | F H1(Hex) | H2 (Hex) Pondus (g) |
PUT06-04 | 6 | 4 | 37.4 | 14.9 | 3.3 | 15.5 | |
PUT08-04 | 8 | 4 | 38.9 | 14.9 | 3.3 | 15.5 | |
PUT08-06 | 8 | 6 | 39.4 | 15.4 | 3.3 | 17.1 | |
PUT10-06 | 10 | 6 | 43.2 | 15.4 | 3.3 | 17.1 | |
PUT10-08 | 10 | 8 | 45.9 | 18.1 | 3.3 | 18.2 | |
PUT12-08 | 12 | 8 | 46.8 | 18.1 | 4.4 | 18.2 | |
PUT12-10 | 12 | 10 | 49.7 | 21.0 | 4.4 | 19.9 |
EXEMPLUM | A | A1 | B | D | E | El | F | Pondus (g) |
PUT06-04 | 6 | 4 | 20.1 | 13.3 | 13.3 | 3 | 6.4 | |
PUT08-06 | 8 | 6 | 22.6 | 14.5 | 14.5 | 3 | 8.7 | |
PUT10-08 | 10 | 8 | 26.5 | 18.2 | 18.2 | 4 | 13.6 | |
PUT12-10 | 12 | 10 | 28.3 | 20.6 | 20.6 | 4 | 19 | |
PUT16-12 | 16 | 12 | 32.5 | 25.2 | 25.2 | 5 | 21.2 |
attention please :Quotations et traditione non-stirpe items suppleverunt petitionem.Configurationes et dimen- siones mutabiles sine nota.
Plastic ventilabis-in Fittings
Features
- Simpliciter ut instituas & amoveas nullis instrumentis.
- Tubam chalybem densis mechanism immaculatam.
- Fila sealant in stamina lychnis, O-anulus faciei sigillum in G stamina.
- NBR ut vexillum materiae obsignandi, aliae materiae postulantibus praesto sunt.
- Nick patella est vexillum ad curationem superficiei bassinae, anti-corrosionis et anti-contaminationis invigilare.
- Reuseable-Potest saepe convocari et disconvenire.(Suadeo ut interficiam superficies, quassatas partem tubi)
- Post: BSPP, BSPT, NPT (Quaeso nos contact aliis generibus)
Specification
O-Ring Sigillum | NBR (alia materiae sunt praesto ad petitionem) |
Tenax Mechanismus | Diver |
Temperatus dolor | 32° F ad 140°F |
Pressura Max | 150 PSI |
Vacuum Officium | 29.5 Inch Hg |
Media | Cogo Air |
Nota: Hi solum ducem in consilio adiuvandi significabant.Agro probatio facienda est ut valores actuales invenias pro applicatione tua.
Institutiones
Figura 1 | Figura 2 |
Ad coniungere fistulam (videre figure I)
- Cut Tubing-maximum 15° angulum permittit. Usus tubuli dromonis (PTC) commendatur.
- Perscriptio portus seu coitus pars munda est et strages expers.
- Tubus inserere in aptam usque ad extrema.Push bis ut verificetur Tubing quod praeteritum collet & O-Ring inseratur.
- Tubing trahere ut verificetur plene inseritur.
Disconnect fistula (vide figure II)
- Solum conjunctionem emissio premunt, contra corpus tene, et de decenti Tubing trahere.