BJM Caulis Ad Male Fistulam ad Pipe aes unum Tactus Fittings
Mod. | G | D | H | T | L | SW | Pondus (g) |
BJM-M04-M5 | 4 | M5 | 4 | 16.5 | 24.5 | 8 | 3 |
BJM-M04-G02 | 4 | Gl/8 | 5.5 | 16.5 | 27.8 | 12 | 10 |
BJM-M05-G2 | 5 | Gl/8 | 5.5 | 18 | 29.3 | 12 | 9 |
BJM-M05-G4 | 5 | Gl/4 | 7 | 18 | 31 | 14 | 11 |
BJM-M06-G2 | 6 | Gl/8 | 5.5 | 18 | 29.3 | 12 | 10 |
BJM-M06-G4 | 6 | Gl/4 | 7 | 18 | 31 | 14 | 12 |
BJM-M08-G2 | 8 | Gl/8 | 5.5 | 20.5 | 31.8 | 12 | 12 |
BJM-M08-G4 | 8 | Gl/4 | 7 | 20.5 | 35.5 | 14 | 13 |
BJM-M10-G4 | 10 | Gl/4 | 7 | 23 | 36 | 14 | 16 |
BJM-M10-G6 | 10 | G3/8 | 8 | 23 | 37.3 | 19 | 25 |
BJM-M12-G6 | 12 | G3/8 | 8 | 24 | 38.3 | 19 | 25 |
BJM-M14-G8 | 14 | Gl/2 | 9 | 28 | 44 | 22 | 59 |
Interchangeability ut referat
Parker : 68PLMSP-4M-M5 68PLMSP-4M-2G 68PLMSP-4M-4G 68PLMSP-6M-2G 68PLMSP-6M-4G 68PLMSP-8M-2G 68PLMSP-8M-4G 68PLMSP-8M-6G 68PLMSP-10M-4G 68PLMSP-10M -6G 68PLMSP-10M-8G 68PLMSP-12M-6G 68PLMSP-12M-8G 68PLMSP-14M-8G
Eton/WeatherHead : 1180x4Mx2PP 1180x5Mx2PP 1180x6Mx2PP 1180x6Mx4PP 1180x8Mx2PP 1180x8Mx4PP 1180x10Mx4PP 1180x10Mx6PP 1180x12Mx6PP
Mediterraneus :
Camozzi :
attention please Quotations et traditione non-stirpe items suppleverunt petitionem.Configurationes et dimen- siones mutabiles sine nota.
Metal/Brass ventilabis-In Fittings
Features
- Simpliciter ut instituas & amoveas nullis instrumentis.
- Tubam chalybem densis mechanism immaculatam.
- Fila sealant in stamina lychnis, O-anulus faciei sigillum in G stamina.
- NBR ut vexillum materiae obsignandi, aliae materiae postulantibus praesto sunt.
- Nick patella vexillum est ad curationem superficiei bassinae, anti-corrosionis et anti-contaminationis invigilandi.
- Reuseable-Potest saepe convocari et disconvenire.(Suadeo ut interficiam superficies, quassatas partem tubi)
- Post: BSPP, BSPT, NPT (Quaeso nos contact aliis generibus)
Construction
Specification
O-Ring Sigillum | NBR (alia materiae sunt praesto ad petitionem) |
Tenax Mechanismus | Diver |
Temperatus dolor | 32° F ad 176°F. |
Pressura Max | 230 PSI (maxime terminatur per tubum permanentem); |
Vacuum Officium | 29.5 Inch Hg |
Media | Cogo Air |
Nota: Hi solum ducem in consilio adiuvandi significabant.Agro probatio facienda est ut valores actuales invenias pro applicatione tua.
Institutiones
Figura 1 | Figure 2 |
Ad coniungere fistulam (videre figure I)
- Cut Tubing-maximum 15° angulum permittit. Usus tubuli dromonis (PTC) commendatur.
- Perscriptio portus seu coitus pars munda est et strages expers.
- Tubus inserere in aptam usque ad extrema.Push bis ut verificetur Tubing quod praeteritum collet & O-Ring inseratur.
- Tubing trahere ut verificetur plene inseritur.
Disconnect fistula (vide figure II)
- Solum conjunctionem emissio premunt, contra corpus tene, et de decenti Tubing trahere.