BF Female Pipe Tube ad Pipe aes unum Tactus Fittings
Mod. | A | D | C | F | G | L | P(min) | SW |
BF-M04-M05 | 4 | M5 | 6.5 | 7.8 | 8.8 | 20.5 | 4.5 | 9 |
BF-M04-G02 | 4 | Gl/8 | 10 | 9 | 13 | 24 | 6 | 12 |
BF-M05-G02 | 5 | Gl/8 | 10 | 9.8 | 15 | 25 | 6 | 12 |
BF-M06-G02 | 6 | Gl/8 | 10 | 11.7 | 13 | 26 | 6 | 12 |
BF-M06-G04 | 6 | Gl/4 | 11.5 | 11.9 | 16.5 | 27.5 | 7 | 15 |
BF-M08-G02 | 8 | Gl/8 | 9.5 | 13.7 | 15.2 | 27 | 6 | 14 |
BF-M08-G04 | 8 | Gl/4 | 11.5 | 15.7 | 16.5 | 29 | 7 | 15 |
BF-M10-G04 | 10 | Gl/4 | 11.3 | 15.4 | 18.5 | 31.5 | 7 | 17 |
Interchangeability ut referat
Parker : 66PLM-4M-M5 66PLM-4M-2G 66PLM-4M-4G 66PLM-6M-2G 66PLM-6M-4G 66PLM8M-2G 66PLM-8M-4G 66PLM-10M-6G 66PLM-12M-6G 66PLM-12M-8G
Eton/WeatherHead :1166×2 1166x2x4 1166×2.5 1166×2.5×4 1166×4 1166×4×4 1166×6 1166x6x6
Mediterraneus : 20-040 20-041 20-043 20-044
Camozzi : ND646353-02 ND646353-04 ND6463 04-02 ND6463 04-04 ND646304-06* ND6463 06-02 ND6463 06-04 ND646306-06 ND646306-08* ND6463 06-12* ND6463 08-02* ND6463 08-04 ND6463 08-06 ND6463 08-08 ND646308-12* ND6463 10-06* ND6463 10-08
Metal/Brass ventilabis-In Fittings
Features
- Simpliciter ut instituas & amoveas nullis instrumentis.
- Tubam chalybem densis mechanism immaculatam.
- Fila sealant in stamina lychnis, O-anulus faciei sigillum in G stamina.
- NBR ut vexillum materiae obsignandi, aliae materiae postulantibus praesto sunt.
- Nick patella vexillum est ad curationem superficiei bassinae, anti-corrosionis et anti-contaminationis invigilandi.
- Reuseable-Potest saepe convocari et disconvenire.(Suadeo ut interficiam superficies, quassatas partem tubi)
- Post: BSPP, BSPT, NPT (Quaeso nos contact aliis generibus)
Construction
Specification
O-Ring Sigillum | NBR (alia materiae sunt praesto ad petitionem) |
Tenax Mechanismus | Diver |
Temperatus dolor | 32° F ad 176°F. |
Pressura Max | 230 PSI (maxime terminatur per tubum permanentem); |
Vacuum Officium | 29.5 Inch Hg |
Media | Cogo Air |
Nota: Hi solum ducem in consilio adiuvandi significabant.Agro probatio facienda est ut valores actuales invenias pro applicatione tua.
Institutiones
Figura 1 | Figure 2 |
Ad coniungere fistulam (videre figure I)
- Cut Tubing-maximum 15° angulum permittit. Usus tubuli dromonis (PTC) commendatur.
- Perscriptio portus seu coitus pars munda est et strages expers.
- Tubus inserere in aptam usque ad extrema.Push bis ut verificetur Tubing quod praeteritum collet & O-Ring inseratur.
- Tubing trahere ut verificetur plene inseritur.
Disconnect fistula (vide figure II)
- Solum conjunctionem emissio premunt, contra corpus tene, et de decenti Tubing trahere.